3-4 wiring methods, Wiring methods, Connecting analog inputs (fqm1-mma21) – Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-MMA21 User Manual

Page 97: Connectors

Advertising
background image

74

Wiring Module Connectors

Section 3-3

Connecting Analog
Outputs (FQM1-
MMA21)

Output signals are connected as shown in the following diagram.

Connecting Analog Inputs (FQM1-MMA21)

Voltage Input

Current Input

3-3-4

Wiring Methods

Either make a cable using the special connector (purchased separately), or
connect to a terminal block using an OMRON special cable with a connector.

Note

(1) Do not apply voltages that exceed the maximum switching capacity of

output circuits and the input voltage of I/O circuits.

(2) Do not mistake positive and negative when wiring power supply, where

there are positive and negative terminals.

(3) To conform to the EC Low Voltage Directive, use a DC power supply for

I/O that has reinforced or double insulation.

(4) Check that the connector wiring has been performed correctly before

supplying power.

(5) Do not pull on cables. Doing so may result in disconnection.

(6) Do not bend cables beyond their natural limit. Doing so may result in dis-

connection.

Connectors

Connecting MIL Connectors

Pin No.

Analog output 2

Shield

38 (V2+)

40 (V2

−)

+

Analog output 1

37 (V1+)

39 (V1

−)

+

40-pin connector

FQM1-MMA21

Pin No.

Shield

Analog input

33 (V1+)

35 (V1

−)

+

Special I/O connector

FQM1

Pin No.

Shield

Analog input

33 (V1+)

35 (V1

−)

+

Special I/O connector

FQM1

34 Current input

Connector type

Number of

pins

Ordering as a set

(OMRON)

DDK Ltd.

Pressure welded

26 pins

XG4M-2630-T

FRC5-A026-3T0S

40 pins

XG4M-4030-T

FRC5-A040-3T0S

Advertising