Troubleshooting Guide

7

7-2

Problem

Solution

Fluid flows in the opposite

1. Check tubing connections to source

direction of what is intended

and drain containers.

2. Check that the motor is rotating in

the correct direction. Refer to
Figure 5-5.

Fluid flow direction cannot

The motor only turns in one

be reversed

direction. Make sure you use a
bi-directional motor.

The tube moves when pumping

Adjust the Clamp Screw. Refer to
Section 5.4.

The Stator will not snap shut

1. Make sure the tubing is loaded

properly. The tubing should be
centered in the middle of the rollers.

2. Make sure the tubing wall thickness

is correct (refer to Table 9-1).

3. The tubing inside diameter may be

too large for the pump. (refer to
Table 9-1).

4. The tubing durometer may be too

high for the pump (refer to Chapter
9).

5. The tubing may be caught on the

bottom roller. Reposition the roller
slightly and load the tubing again.

Screws are too short to fasten

Use long mounting screws

two stacked pumps to the motor

(Part Number FPU500-LMS)