Slide number 15, Gas hook-up, Installer final check list – Olfa 720-0430 User Manual
Page 15
 
GAS HOOK-UP
5.
When connecting regulator assembly to the valve,
hand tighten the quick coupling nut clockwise to 
a complete stop. Do not use a wrench to tighten. 
Use of a wrench may damage the quick 
coupling nut and result in a hazardous condition.
6. Open the tank valve fully (counterclockwise).
Use a soapy water solution to check all 
connections for leaks before attempting to light 
the grill, see below. If a leak is found, turn the 
tank valve off and do not use the grill until a 
local L.P. gas dealer can make repairs.
To disconnect L.P. gas cylinder:
1. Turn the burner valves off.
2. Turn the tank valve off fully (turn clockwise to
stop).
3. Detach the regulator assembly from the tank
valve by turning the quick coupling nut 
counterclockwise. 
INSTALLER FINAL CHECK LIST
9 Specified clearance maintained
24”(61cm) from combustibles.
9 All internal packaging removed.
9 Knobs turn freely.
9 Burners are tight and sitting properly 
on orifices.
9 Pressure regulator connected and set.
Gas connections to grill using hose &
regulator assembly provided (pre-set
for 11.0” water column).
9 Unit tested and free of leaks.
9 User informed of gas supply shut off 
valve location
USER, PLEASE RETAIN THESE 
INSTRUCTIONS FOR FUTURE 
REFERENCE.
PROPANE CYLINDER CAUTIONS
a) Do Not store a spare LP-gas
cylinder under or near this 
appliance.
b) NEVER fill the cylinder beyond 80
percent full.
c) If the information in “a” and “b” is
not followed exactly, a fire causing 
death or serious injury may occur.
14