Slide number 16, Leak testing – Olfa 720-0430 User Manual
Page 16
 
LEAK TESTING
GENERAL
Although all gas connections on the grill are leak 
tested at the factory prior to shipment, a complete 
gas tightness check must be performed at the 
installation site due to possible mishandling in 
shipment, or excessive pressure unknowingly being 
applied to the unit. Periodically check the whole 
system for leaks following the procedures listed 
below. If the smell of gas is detected at anytime you 
should immediately check the entire system for 
leaks.
BEFORE TESTING
Make sure that all packing material is removed from 
the grill including the burner tie-down straps.
DO NOT SMOKE WHILE LEAK TESTING.
NEVER PERFORM LEAK TEST WITH AN OPEN 
FLAME.
Make a soap solution of one part liquid detergent 
and one part water. You will need a spray bottle, 
brush, or rag to apply the solution to the fittings. For 
the initial leak test, make sure the L.P. cylinder is full.
TO TEST 
1. Make sure the control valves are in the “OFF” 
position, and turn on the gas supply. 
2. Check all connections from the LP gas regulator 
and supply valve up to and including the connection 
to the manifold pipe assembly (the pipe that goes to 
the burners). Soap bubbles will appear where a leak 
is present. 
3. If a leak is present, immediately turn off the gas 
supply and tighten the leaky fittings. 
4. Turn the gas back on and recheck. 
5. Should the gas continue to leak from any of the 
fittings, turn off the gas supply and contact customer 
service at 1-800-913-8999. 
Only those parts recommended by the 
manufacturer should be used on the grill. 
Substitution will void the warranty. Do not use the 
grill until all connections have been checked and 
do not leak.
GAS FLOW CHECK:
Each grill burner is tested and adjusted at the 
factory prior to shipment; however, variations in the 
local gas supply may make it necessary to adjust 
the burners. The flames of the burners should be 
visually checked.
Flames should be blue and stable with no yellow 
tips, excessive noise or lifting. If any of these 
conditions exist, check to see if the air shutter or 
burner ports are blocked by dirt, debris, spider 
webs, etc. If you have any questions regarding 
flame stability, please call customer service 1-800- 
913-8999 .
ALWAYS CHECK FOR LEAKS 
AFTER EVERY L.P. TANK CHANGE
Check all gas supply fittings for 
leaks before each use. It is handy to 
keep a spray bottle of soapy water 
near the shut-off valve of the gas 
supply line. Spray all the fittings. 
Bubbles indicate leaks.
15