1 run modes – Omega RD100B User Manual

Page 78

Advertising
background image

4-1

Common Operations for Setting Functions and Setup Guide

4

4.1

Run Modes

The recorder has three run modes.

Operation Mode

This mode is used for normal recording operation. The recorder enters this mode when

the power is turned ON. The operations that can be carried out in this mode are

described in chapter 3. The details on the data display setup screen are explained in

chapter 8.

Setting Mode

This mode is used to set the input range, alarms, chart speed, and other parameters.

These settings can be changed while recording is in progress. However, the input range

of measurement channels and the computing equation, unit, constant, and TLOG setting

of computation channels cannot be changed while computation (/M1 option) is in

progress. The operations that can be carried out in this mode are described in chapter 5

and 6.

Basic Setting Mode

This mode is used to set the basic specifications of the recorder such as the

thermocouple burnout detection function and the alarm output relay operation. This

mode cannot be entered while the recorder is recording or while computation is in

progress on the computation function (/M1 option). Measurement, recording, and alarm

detection cannot be carried out in this mode. The operations that can be carried out in

this mode are described in chapter 7.

Operation mode

Power ON

Setting mode

Data display setup screen

Basic Setting mode

MENU

1

Display “End=Store” and press

MENU

Hold down
for 3 s

Hold down

Hold down

+

for 3 s

for 3 s

Chapter 4 Common Operations for Setting Functions and Setup Guide