Appendix C

Using an RS-232C/RS-422A Convertor Unit

263

Pin Arrangement

The convertor unit has a terminal block for an RS-422A/485 interface connection and a connector for an RS-232C
interface connection.

The pin arrangements for the RS-422A/485 terminal block and the RS-232C connector are as follows.

RS-422A/485 Terminal Block

Terminal

block pin

No.

Signal name

Abbreviation

Signal direction

(convertor unit

RS-422

device)

8

Request to send (

−)

CSA

7

Request to send (+)

CSB

6

Receive data (

−)

RDA

5

Receive data (+)

RDB

4

Send data (

−)

SDA

3

Send data (+)

SDB

2

Signal ground

SG (GND)

1

Functional ground

* The CSB and CSA signals are for specialized applications.

RS-232C Connector

Connector

pin No.

Signal name

Abbreviation

Signal direction

(convertor unit

RS-232C

device)

1

Not used

2

Send data

SD

3

Receive data

RD

4

Request to send
(shorted to CS internally)

RS

5

Clear to send
(shorted to RS internally)

CS

6

+5 V (150 mA) input for convertor
unit

+5 V

7

Data set ready
(shorted to ER internally)

DR

8

Data terminal ready
(shorted to DR internally)

ER

9

Signal ground

SG

* The hood is connected to the functional ground terminal of the RS-422A terminal block.