WARNING

1. The F3S-B is a TYPE 2 electro-sensitive protective equip-

ment, intended to be used as or with the safety related part

of control system to category 2,1, or B as defined in the

European standard EN954-1.
Do not use the F3S-B in category 3 or 4 systems.

2. A qualified person, as determined by local regulations,

must confirm that installation, inspection and maintenance

are implemented correctly.

3. Do not short the output lines to the +24 V line. Doing so will

cause the output to be always ON, creating a hazardous

situation.

4. Do not connect the F3S-B to a power supply with voltage

higher than 24 VDC + 20%. Do not connect the F3S-B to

an AC power supply.

5. Be sure to conduct inspections regularly.
6. The F3S-B cannot be used in applications where hazard-

ous projectiles may exit the protected zone.

7. Do not disassemble, repair, or modify the F3S-B.
8. DC power supply units must satisfy all of the conditions

below so that the F3S-B can comply with the applicable

standards IEC 61496-1 and UL 508.

(1.) The power supply voltage must be within rating

(24 VDC ± 20 %).

(2.) The power supply is connected only to the F3S-B and

to the electro-sensitive protective function of the

F3S-B, such as a safety controller and muting

sensors, and it has enough rated current for all the

devices.

(3.) The power supply uses double or reinforced insulation

between the primary and secondary circuits.

(4.) The power supply automatically resets overcurrent

protection characteristics (voltage drop).

!

(5.) The power supply maintains an output holding time

of at least 20 ms.

(6.) FG (frame ground terminal) must be connected to

PE (protective earth) when using a commercially

available switching regulator.

(7.) The power supply must have output characteristics

required for the power source for Class 2 Circuit or

Limited Voltage/Current Circuit as defined in UL508.

(8.) The power supply must conform to regulatory

requirements and standards, regarding EMC and

electrical equipment safety, of the country where the

F3S-B is installed and where machinery will be

operated. For example: The EMC Directive

(industrial environment) and the Low Voltage

Directive in EU.

9. Do not use the F3S-B in a retroreflective configuration, or

detection may fail.