Specifications, F3s-b – Omron F3S-B User Manual

Page 4

Advertising
background image

F3S-B

5

Specifications Table

-- continued from previous page

Type

F3S-BjjjP (See Note 1)

Stand-Alone

F3S-BjjjPjj (See Note 1)

Master Unit for series connection

F3S-Bjjj (See Note 1)

Master Unit for series connection

Protective height

300 / 450 / 600 / 750 / 900 / 1,050 / 1,200 / 1,350 / 1,500 / 1,650 mm

300 / 450 / 600 / 750 mm

Detection distance

0.3 to 5.0 m

Response time

ON to OFF: See table Response Time
OFF to ON (See note 2): Default 100 ms (selectable with F39--U1E, 80 to 400 ms)

Startup waiting time

2 s max.

Supply voltage: Vs

24 VDC ±20% (including 5 Vp-p ripple)

Current consumption

400 mA max. (under no-load conditions)

Light source

Infrared LED (880 nm wavelength). Lifetime: 50,000 hrs. at 25 °C.

Effective aperture angle Within ±5° for the emitter and receiver at a detection distance of at least 3 m according to IEC 61496--2
Operating mode

Light ON

Control output

Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop

due to cable extension)

Instability output

PNP transistor output (not safety--related control output),

activated during an insufficient light detection, failure detection and connection with F39--E1,
load current 100 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension)

Protection circuit

Output short--circuit protection, power supply reverse connection protection

Start/restart interlock

Mode selection before power ON by connecting Interlock selection input line to:

Start/restart interlock

function

Mode selection before power ON by connecting Interlock selection input line to:

Active: No connection or 0 to 2.5 VDC, 3 mA max.

function

Active: No connection or 0 to 2.5 VDC, 3 mA max.

Inactive: Instability output line

Inactive: Instability output line

Reset of start/restart interlock by connecting Interlock selection input line to:

Reset of start/restart interlock by connecting Interlock selection input line to:

Interlock reset: 17 VDC to Vs, 20 mA max. Duration time 15 to 2,500 ms

External test function

Mode selection by connecting External test input line to:

External test function

Mode selection by connecting External test input line to:

Active: 17 VDC to Vs, 10 mA max. Duration time at least 15 ms

I

i

N

i

VDC

A

Active: 17 VDC to Vs, 10 mA max. Duration time at least 15 ms

Inactive: No connection or 0 to 2.5 VDC, 2 mA max.

Relay monitoring

Default inactive, selectable with F39--U1E

Relay monitoring

function (optional)

Default inactive, selectable with F39--U1E

Relay monitoring input line with NC contact connected

function (optional)

Relay monitoring input line with NC contact connected

Available level: 17 VDC to Vs, 10 mA max.

Available level: 17 VDC to Vs, 10 mA max.

Allowed relay delay time: Selectable between 20 and 300 ms (See Note 2)

Allowed relay delay time: Selectable between 20 and 300 ms (See Note 2)

Termination when not selected: No connection or 0 to 2.5 VDC, 2 mA max.

Start interlock function

(optional)

Default inactive, selectable with F39-U1E

Blanking function

(optional)

Default inactive, selectable with F39-U1E

Indicator

See Indicators

No Indicators

Connection method

For Extension cable: 8 pins M12 connector For Series connection cable: 6 pins M12 connector

Connection method

For Extension cable: 8 pins, M12 connector. For Series connection cable: 6 pins, M12 connector

Ambient temperature

During operation: -10 to 55 °C (with no freezing)

During storage: -25 to 70 °C

Ambient humidity

During operation: 35 to 85 %RH (with no condensation)

During storage: 35 to 95 %RH

Insulation resistance

20 MΩ min. (at 500 VDC)

Dielectric strength

voltage

1,000 VAC 50/60 Hz for 1 min

Degree of protection

IEC60529 IP65

Vibration resistance

Normal operation: 10 to 55 Hz, double--amplitude: 0.7mm, X, Y and Z directions 20 sweeps

Shock resistance

Normal operation: 100 m/s

2

[10 G], X, Y and Z directions: 1000 times

Materials

Case: Aluminum

Front cover: PMMA (acrylic resin)

End caps: PA6

Size (cross-section)

30 x 40 mm

Accessories

Test rod (See Note 3); mounting brackets -- top and bottom, mounting brackets -- intermediate (See Note 4);

mounting plates (See Note 4); instruction manuals (See Note 5).

Applicable standards

IEC(EN)61496-1 Type 2 ESPE (Electro-Sensitive Protective Equipment)

IEC 61496-2 Type 2 AOPD (Active Opto-Electronic Protective Devices)

Note:

1

For detailed type names and optical specifications, see Ordering Information.

2

Nominal value (set time). The accuracy is --0. +70% of the ON to OFF response time.

3

Only with F3S--Bjjj2P and BMjjj2Pjj

4

For the 1,050 mm protective height and longer types.

5

Only with F3S--BjjjPj and BMjj2Pjj.