JP6 : User Timer/Counter Clock Input

Selection







Internal 2M
Clock
(default)

INTCLK

EXTCLK

External
Clock

INTCLK

EXTCLK

The OME-A-822PGL/PGH has 3 independent 16 bit timer/counters.

The cascaded counter1 and counter2 are used as a pacer timer. Counter0 can
be used as a user programmable timer/counter. The user programmable
timer/counter can be set to 2M internal clock or external clock ExtCLK,
CN3 pin 37
. The block diagram is given in section 2.6. The clock source must
be very stable. Using the 2M internal clock is strongly suggested.

The OME-A-822PGL/PGH software driver uses counter0 as a machine

independent timer. If users program calls the A-822_Delay() subroutine,
counter0 will be programmed as a machine independent timer. More detailed
information is provided in section 2.6.

NOTE : if you use A-822_Delay(), the JP6 jumper must
be set to internal 2M clock.

OME-A-822PGL/PGH Hardware Manual ---- 14