A/d multiplex control register, Ome-a-822pgh gain control code table, 7 a/d multiplex control register – Omega ISA- BUS MULTI-FUNCTIONAL BOARD OME-A822PG User Manual

Page 23

Advertising
background image

OME-A-822PGH GAIN CONTROL CODE TABLE


BI/UN Settling Time GAIN Input Range

GAIN3 GAIN2 GAIN1 GAIN0

BI 23

us 1 +/-

5V 0 0 0 0

BI

28 us

10

+/- 0.5V

0

0

0

1

BI

140 us

100

+/- 0.05V

0

0

1

0

BI

1300 us

1000

+/- 0.005V

0

0

1

1

UNI

23

us 1 0

to

10V 0 1 0 0

UNI

28 us

10

0 to 1V

0

1

0

1

UNI

140 us

100

0 to 0.1V

0

1

1

0

UNI

1300 us

1000

0 to 0.01V

0

1

1

1

BI

23 us

0.5

+/- 10V

1

0

0

0

BI 28

us 5 +/-

1V 1 0 0 1

BI

140 us

50

+/- 0.1V

1

0

1

0

BI

1300 us

500

+/- 0.01V

1

0

1

1

BI=Bipolar, UNI=Unipolar, X=don‘t care, N/A=not available

2.4.7 A/D Multiplex Control Register


(WRITE) Base+A : A/D Multilexer Control Register Format
Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

X X X X D3 D2 D1 D0
A/D input channel selection data = 4 bits : D3..D0, D3=MSB, D0=LSB, X=don‘t care
Single-ended mode : D3..D0
Differential mode : D2..D0, D3=don’t care


The OME-A-822PGL/PGH provides 16 single-ended or 8 differential analog input signals.
In single-ended mode, D3..D0 selects the active channel. In differential mode, D2..D0 selects
the active channel and (D3 has no affect).
NOTE: The settling time of the multiplexer depends on the resistance.of the input
sources.
source resistance = about 0.1K ohm
Æ settling time = about 3 us.
source resistance = about 1K ohm
Æ settling time = about 5 us.
source resistance = about 10K ohm
Æ settling time = about 10 us.
source resistance = about 100K ohm
Æ settling time = about 100 us.