Electrical information, Caution, Warning – Quadra-Fire QVI-25FB-S User Manual

Page 18

Advertising
background image

Quadra-Fire • QVI-25FB-S • 2031-910 Rev. G • 6/09

18

A. Wiring the Appliance

9

9

Electrical Information

Note: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition
or the Canadian Electric Code, CSA C221.1.

ON/OFF Switch

• An ON/OFF switch is included with the decorative

surround/decorative front and should attached to
surround/facing. (See Installation instructions for remote
control).

• If desired an additional wall switch or thermostat may

be added to system as shown in Figure 9.1.

Appliance Requirements

• This appliance DOES NOT require 110-120 VAC to

operate.

• It is recommended that a 110 VAC junction box be

connected for use with fan or remote control. (See Figure
9.2 for junction box wiring).

• Prevent accidental appliance operation when not attended.

• Unplug or remove batteries from remote control if absent or

if appliance will not be used for an extended period of time.

• Property damage possible from elevated temperatures.

CAUTION

ON

OFF

ON/OFF

SWITCH

REMOTE SWITCH

PIGTAIL

OPTIONAL WALL SWITCH,

THERMOSTAT OR REMOTE

STANDING

PILOT

WHT

RED

VALVE

Note: Electrical wiring must be installed by a licensed
electrician.

Figure 9.1 Standing Pilot Ignition Wiring Diagram

Wire 110V to electrical junction box.

Do NOT wire 110V to valve.

Do NOT wire 110V to wall switch.

• Incorrect wiring will damage millivolt valves.

• Incorrect wiring will override IPI safety lockout

and may cause explosion.

WARNING

• A 110-120 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.