Quadra-Fire • QVI-25FB-S • 2031-910 Rev. G • 6/09

20

Figure 9.4 Fan Wiring Diagram

JUNCTION BOX

VARIABLE SPEED CONTROL

TEMPERATURE

SENSOR SWITCH

WHT

GRN

BLK

BLK

110-120 VAC

BLOWER

BLOWER RECEPTACLE

BLK

BLK

BLK

BLK

WHT

GROUND

WHT

BLK

BLK

BLK

REMOTE

RECEPTACLE

INSERT STUD THROUGH HOLE
AND SECURE WITH WING NUT

WING

NUT

TEMP SWITCH

BRACKET

FAN

TEMPERATURE
SENSOR SWITCH

SPEED CONTROL
(RHEOSTAT)

REMOTE
OUTLET

FAN
OUTLET

BEND UP
TABS

JUNCTION BOX

NOTE: If any of the original wire as supplied
with the appliance must be replaced, it must be
replaced with type 105º crated wire.

NOTE: Do NOT install blower if using operable
glass doors.