Detecting formats supported by a monitor, Learn monitor – Quantum Data 700A User Manual

Page 12

Advertising
background image

12

Model 700A, 701A Quick Start Guide

_______

Reading

_____

Monitor EDID

_______

COMPLETE

Details

Show details of EDID
after successful read
back from display
under test

Complete indicates EDID
data was read back
correctly.
Failed indicates unable to
read back valid EDID data

Learn Monitor

If the generator is connected to a VESA DCC-

compliant display, press the Learn Monitor

button to view formats supported by both the

display and generator.

To view the format names, select the Details

option after the generator completes reading

the EDID (Extended Display Identification Data)

data. The display’s EDID data may include

non-VESA formats, which are not listed.

You cannot select formats from this list, but the

DDC Step feature can be used to test the listed

formats (page 14).

Detecting Formats Supported by a Monitor

Advertising