Functional Specifications

Quantum A-Series Tape Drives User’s Guide

40

Table 14 Power Requirements
— SCSI Interface

Mode

DC Power
MaxPk

1

Typ

2

AC Power (W)
Max

3

Typ

4

Standby/Idle

21

21

51

46

Media Loading/Unloading

43

37

83

73

600A Write – Motor Start

5

32

29

78

71

600A Write – Streaming

32

31

73

64

Max for SDLT 600A tape drive Modes

6

43

N/A

83

N/A

1.

The Max-Peak value represents short current spikes drawn for durations of < 50ms. On the 12V supply, the
peaks correspond to the pulse-width-modulated switching of the motors. These values are calculated from the
average of Peak-ripple-current + 2 sigma, measured at nominal DC voltage.

2.

The typical current is calculated from the average of all RMS current drawn during this operating mode,
measured at nominal DC voltage.

3.

The Max AC power is calculated from the typical AC power in tabletop tape drives + 3 sigma.

4.

The Typical AC power is calculated from the average of AC power drawn in tabletop tape drives.

5.

These events last < 1 second and occur at a duty cycle of less than 25%.

6.

The Max values for each mode are based on the Max-Mean values, since the peak values are of very short
duration.

(Common Notes)
(1) Voltage tolerance: 5V ±5%, 12V ±5%; Room temperature 24 °C. AC power measured at 117 V, 60 Hz.
(2) DC Current, MaxMean, and DC/AC Power Max refer to the statistically calculated maximum average

requirement based on a sample population of tape drives. These values do not reflect the peak current or power
requirement; this amount is given by the DC MaxPk current.

(3) These results were from the DVT data taken by Percept Technology. Reference the “Power Consumption &

Characterization Test Report” dated 11/28/2005.

(4) Test data set included 12 measurements: 3 measurements of 4 drives.
(5) The 5V “MaxPK” calculated to less than MaxRMS, which does not at first glance make sense. (MaxPK is

calculated at 5.25V, and the switching power supplies need less input current to the same input current.)
Instead, the MaxRMS value was substituted.