SERLA and SERLB Connectors

on Executive IV PCBA

FCO_A Connector on

Fibre Channel Option

SERIAL Ribbon Cables

Note: Red edge faces right.

AUXPWR Connector
on Executive PCBA

PWRIN Connector on

Fibre Channel Option

AUXPWR Cable

Q_LINK Connector on

Fibre Channel Option

Figure 4-13 Detail of Connections (Executive IV PCBA Shown)

11.

Carefully lift the FCO until it touches the rear of the TLS. Using a Phillips
screwdriver, secure the Fibre Channel Option to the rear of the TLS by tighten-
ing all four of the captive screws. Refer to Figure 4-9 for captive screw locations.

12.

Install the FCO serial communication bridge cable. The serial communication
bridge cable is a short telephone type cable with a six-conductor RJ11 plug on
each end. Insert each ended of the serial communication bridge cable (P/N-
510149-01-6) into the RJ11 jacks on the FCO. See Figure 4-14.

External Cable to

Host Ethernet Interface

(RJ45)

Reset Button

Serial Jumper

Connectors

(RJ11)

SCSI Channel 0

SCSI Channel 1

Fibre Channel 0

SFP Interface

Serial Communication

Bridge Cable

FCO Type C Installation

501440 Rev. J

4-14