4 Troubleshooting

3EC 37891 AAAA TCZZA Ed. 01

43

How to perform a

hardware reset to

factory defaults

Proceed as follows:

Factory default service

settings

When the SpeedTouch™ leaves the factory and after every hardware reset to defaults,
the SpeedTouch™ features the following factory default settings:

Default IP configuration:

IP address: 10.0.0.138

Auto IP address

System password: not set

DHCP server: disabled

DNS server: disabled

Master firewall: enabled

Default Connection profile settings:

IEEE802.3D Transparent Bridging on VPI*VCI=8*35

IEEE802.3D Transparent Bridging on VPI*VCI=0*35

Step

Action

1

Make sure the SpeedTouch™ is powered off.

2

Press the power button once (shortly).

3

As soon as the Power/System LED is flashing green, press the power button
once more (shortly).

4

The Power/System LED stops flashing to become solid green. After six
seconds, it starts flashing green again. Press the power button once more
(shortly).

5

All LEDs flash green once.

6

The SpeedTouch™ reboots and will come online with factory default settings.

Resetting the system to its factory defaults also involves deleting the configu-
ration profile settings. You may, therefore, need to reconfigure the system
using the SpeedTouch™ Setup wizard or by uploading the relevant configura-
tion file. See section

“1.3 SpeedTouch™ Configuration Setup” on page 13

for

more information.