About the contact input/ output terminal – TOA Electronics N-CC2360 User Manual

Page 12

Advertising
background image

12

No.

1

2

3

4

5

6

IN 1

IN 2

C

OUT 1

OUT 2

C

Contact input 1

Contact input 2

COM

Contact output 1

Contact output 2

COM

Terminal Name

Contact name

Day/ Night

Select Contact input 1

or Contact input 2.

COM

IN

GND

1 2 3 4 5 6

Color: Open
Black & white: Closed

The figure shows that IN1 Contact
Input/Output terminal is set to
Day/Night Input terminal position.

24V

24V

2 1

1 2 C 1 2 C

10/100M

AUDIO

OUT

MONITOR

OUT

OUT

IN

CONTACT

RDY BUSY ERR

FD/COL

LINK
/ACT

• Contact Output
There are two contact outputs, allowing external connected device control and contact bridging between video
network system devices. For details, refer to the Setup Manual.

Applicable cables
Solid cable:

AWG28 (ø 0.32) – AWG22 (ø 0.65)

Stranded cable: AWG28 (0.08 mm

2

) – AWG22 (0.32 mm

2

)

Note: Strip the cable sheath approximately 10 mm, then insert the cable while pushing down the button on the

terminal with a screwdriver.

• Contact Input
There are two no-voltage contact inputs for connection of sensor trigger signals, etc. A contact can be
automatically established between the transmitter and the network video receiver or network digital recorder
when a signal enters the contact.
Setting the contact input to Day & Night mode forcibly, shorting (making) the Day/Night input terminal forcibly
switches the display to B&W mode, which increases the camera’s sensitivity. For details, refer to the Setup
Manual.

Note
The Day & Night function can also be set using the camera menu. If "Normal," "Motion," or "Color" has been
selected for the Day & Night function, the display could repetitively switch between color and black-and-white
modes when the camera is used under phototransmitter. In such cases, select "Day & Night" in the "Contact
Input" settings, and synchronize the phototransmitter power supply with the switch to black-and-white mode.
The display mode changes as follows if the Contact Input has been set to "NO" (Normally Open):

Infrared phototransmitter power "ON" :

B&W mode (close)

Infrared phototransmitter power "OFF" : Color mode (open)

10. ABOUT THE CONTACT INPUT/ OUTPUT TERMINAL

Advertising