10

Resetting The Control

Refers To Older Control Versions Only

If memory reaches capacity during a chill cycle there is potential that some printout data could
be incorrect (date & time). This will reset on it’s own, however to do so manually...

FACTORY SETTINGS

VERSION 2.0

S/N:T00000A00

RESET

NEXT

STEP 6

Serial number will be

displayed. Press NEXT.

STEP 5

FACTORY SETTINGS
menu. Press RESET.

STEP 10

Press NEXT.

DEFROST TIME (40)

DEFR. TEMP (50)

°

F

DEFR. INTVL (3) HR

BACK

NEXT

STEP 9

Press NEXT.

STEP 13

Press YES.

STEP 11

Press ENTER.

(do not change code)

S E L E C T S U P E R V I S O R :

PRESET SUPERVISOR

PASSWORD

(PIN): 00

CANCEL ENTER

BLASTING DIFF (4)

°

F

HOLDING DIFF (3)

°

F

ANTI-SHORT(1)

BACK

NEXT

ENTER SECURITY CODE

FOR NEXT SETTINGS:

(000000)

EXIT

ENTER

FACTORY SETTINGS

DO YOU WISH TO SAVE

THESE NEW SETTINGS

NO

YES

STEP 1

Main Menu display press MORE

STEP 2

Press SETUP.

STEP 3

Enter PASSWORD/PIN 85.

S E L E C T S U P E R V I S O R :

TIM SMITH

PASSWORD

(PIN): 85

CANCEL ENTER

DISPLAY WILL SHOW

SELECT SUPERVISOR screen

MAIN MENU AIR 35

°

F

BY TEMP BY PROD
BY TIME

08:05:01

MORE

MAIN MENU 08:06:01

HOLD PROD PRINT
DEFROST

SETUP

BACK

STEP 4

Press the top left, top

right, and bottom right buttons

at the same time.

FACTORY SETTINGS

VERSION 2.0

S/N:T00000A00

RESET

NEXT

LABEL PRINTER (NO)

RESET NEXT

LABEL PRINTER(YES)

RESET

NEXT

STEP 7

Display will ask LABEL

PRINTER (NO), press the UP

arrow to select YES.

STEP 8

Press NEXT.

NEW SOFTWARE

HAS BEEN INSTALLED

SYSTEM PARAMETERS

HAVE BEEN SET!

DISPLAY WILL SHOW

MACH. MODEL (RBC)

MACHINE SIZE(50)

RESET

EXIT

STEP 12

MACH. MODEL (RBC)

MACHINE SIZE(50)

RESET

EXIT

14. The display will return to the MAIN

MENU. Repeat steps 1-10

15. Press EXIT.

16. Press YES.

Display will ask MACHINE SIZE. Press RESET,
then using the UP or DOWN arrow change for
your model. For RBC50 = 50, RBC100 = 100,
RBC200 = 200. Press EXIT.