Triax diagnostic indications – Technicolor - Thomson LDK 4502 User Manual

Page 57

Advertising
background image

Diagnostics

User's Guide LDK 4502 - HDTV Camera Base Station

5-3

Triax diagnostic indications

Camera test LED (4) flashes red

A red flashing camera test LED (4) indicates an open
triax connection (no camera is connected). Other
indicators of this condition are:

OCP:

Triax LED Flashes red

MCP:

DIAGNOSE \ TRIAX - OPEN

Menu:

Diagnostics \ Communications \
Camera Connected -No

Camera test LED (4) lights continuously (red)

A continuously lighting red camera test LED (4) indicates
a short circuit in the triax connection (or an interrupted
inner core). Other indicators of this condition are:

OCP:

Triax LED red (continuously)

MCP:

DIAGNOSE \ TRIAX - SHORT

Menu:

Diagnostics \ Board Diagnostics \ Power

board \ Triax Status -TSHRT, COPEN
or CSHRT (The interpretation of these
messages is shown below)

No Connection

CSHRT

Indicates a short circuit between the core and the
inner shield.

COPEN

Indicates a connection between outer and inner
shield or between core and outer shield (when a
camera is not connected).

It also indicates an interruped inner core when both
shields are connected correctly (when a camera is
connected).

Connected

Connected

Interrupted

SOPEN

Indicates an open connection in the outer shield
of the Triax cable or connector(s).

TSHRT

Indicates a short circuit between the inner shield,
the outer shield and the core.

Precautions to avoid Triax problems

•

Only use triax cable (with three conductors).

•

Ensure that triax connectors (camera, CPU and
extension cables) fit snugly into each other.

•

Verify that there is no interruption in all three
conductors of the triax cable before deploying
(including extension triax cables).