Assembly installing national pipe fittings, Husco load sense line installation – Tiger Products Co., Ltd JD 72-7520 User Manual

Page 33

Advertising
background image

Assembly Section 2-9

ASSEMBLY

INSTALLING NATIONAL PIPE FITTINGS

Whenever installing a pipe fitting, wrap the threads clockwise (looking at the end)

with teflon tape. In this way, the tape will be tightened when installed. NOTE: It is
not necessary to tape O-ring fittings, or those installed in swivels.

HUSCO LOAD SENSE LINE INSTALLATION

To install the load sense line from a Husco valve to the tractor remote valve, first

locate the load sense port located on the bottom of the end cap. Remove the plug and
install 14mm elbow, then attach the 1/4” hose to the end cap and to the top front port on
the Husco valve.

For more information refer to the Parts Section pages for a complete diagram of the

tractor valve hookup.

PRESSURE

RETURN

LOAD SENSE END

2004 UPDATES APPLY TO THESE MODEL’S

JD6000 SERIES SERIAL #’S WITH THIS CHANGE: 391333, 391640, 392239, 395891, 396190, 397161,
396515, 396572, 396560, 396777, 396754, 396764, 396981, 397327, 396983, 396987, 397165, 397159,
397211, 397773, 397450, 397354, 397341, 397498, 397527, 397520, 397360, 397475, 397538, 397569,
397554, 397545, 397585, 397506, 397570, 397587, 397575, AND MODEL #’S STARTING WITH #398797.

JD7000 SERIES SERIAL#’S WITH THIS CHANGE START AT: 12451

HUSCO
VALVE

LOAD SENSE