In/Out Annunciation

The in/out annunciation indicators can be turned on or
off from any master station by using the personal number

registering procedure.

When a personal number registration is made at a station,

by dialing

Confirmation tone

1000~1999 (personal number)

the personal number is registered at that station and the

personal number lamp on the in/out indication panel is

turned on.

Personal number call
By dialing

1000~1999 (personal number)

from any station, the personal number is cancelled and
the personal number lamp on the in/out indication panel

is turned off.

1. The maximum number of in/out annunciation windows

is 1000.

This maximum number remains the same even when the

number of exchanges to be connected is increased to 2
or 3.

2. The in/out indication panel must be used with the Data

Transmitting and Receiving Units (DT-E60 and DR-B61).

In/out indication panel

. . .

Lamp on

Personal number

In/out indication panel

Lamp off

Personal number

1000~1999 (personal number)

from any station, the call is put through to the station

registered with the personal number.

Cancelling personal number and turning off

in/out annunciation.

By dialing

Confirmation tone