Cable specifications, Technical specifications, Continued copper cable – Transition Networks E-100BTX-FX-05 User Manual

Page 6

Advertising
background image

10

E-100BTX-FX-05

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

Cable Specifications

-- Continued

Copper cable

Category 5: (minimum requirement)
Gauge:

24 to 22 AWG

Attenuation:

22.0 dB /100m @ 100 MHz

Maximum Cable Distance:

100 meters

• Straight-through OR crossover cable may be used.
• Shielded twisted-pair (STP) OR unshielded twisted-pair (UTP) may be used
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:

(e.g., blue/white & white/blue, orange/white & white/orange, etc.)

• Do not use flat or silver satin wire.

Straight-Through Cable

Crossover Cable

Twisted Pair #1

Twisted Pair #2

Twisted Pair #2

Twisted Pair #1

[email protected] -- Click the “Transition Now” link for a live Web chat.

11

Technical Specifications

For use with Transition Networks Model E-100BTX-FX-05(xxxx) or equivalent

Standards:

IEEE 802.3

Data rate:

100 Mb/s

Dimensions:

4.75" x 3.0" x 1.0" (119mm x 76mm x 25mm)

Weight:

6 oz. (181 g) approximate

MTBF

46,768 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
123,821 hours (Bellcore7 V5.0)

Power supply:

(standard temperature)

12 VDC, 0.5 A (minimum)

DC output:

(extended temperature)

9 VDC, 1.0 A (minimum)

minimum output regulation: 5%

Environment:

Tmra* (standard temp):

0°C to 50°C (32 to 122°F)

Storage Temperature:

-15°C to 65°C (5 to 149°F)

Tmra* (extended temp):

-25°C to 65°C (-13 to 149°F)

Storage Temperature:

-25°C to 65°C (5 to 149°F)

Humidity:

10% – 90%, non-condensing

Altitude:

0 to 10,000 feet

Warranty:

Lifetime

*Manufacturer’s rated ambient temperature.

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J
applicable at the date of manufacture.

CAUTION: Visible and invisible laser radiation when open. Do not stare into beam or view
directly with optical instruments.

CAUTION: Use of controls, adjustments or the performance of procedures other than those
specified herein may result in hazardous radiation exposure.