For both ins tallation method – Thermador HMWB36 User Manual

Page 10

Advertising
background image

Fix Duct to transition and seal with tape.

For both ins tallation method :

10. Wiring the HOOD:

WARNIN G:

Electrical

Shock Hazard

Turn off power at the service
panel before wiring this unit .
120 VAC, 15 or 20 Amp circuit
required .

ELECTRICAL

GROUNDING

INSTRUCTIONS

THIS APPLIANCE

IS FITTED WITH AN

ELECTRICAL

JUNCTION

BOX WITH 3

WIRES,

ONE OF WHICH (GREEN/YELLOW)

SERVES

TO GROUND THE APPLIANCE.

TO PROTECT

YOU AGAINST ELECTRIC

SHOCK,

THE GREEN AND YELLOW

WIRE MUST BE

CONNECTED TO THE GROUNDING

WIRE IN

YOUR HOME ELECTRICAL SYSTEM, AND IT MUST
UNDER NO CIRCUNSTANCES BE CUT OR REMOVED.

Failure to do so can result in death or
electrical shock.

Final installation steps

1. Install grease filters, lamps and drip trays as

described in the Care & Use section of this
manual .
Note : Lamps are not supplied, use ONLY 120
Volt, 50 Watt (maximum) 50° halogen light
made for a GU10 base, suitable for use in
open luminarie
.
Turn power on at service panel.

10

To Avoid

WARNIN G:

t

Remove the j-box cover as shown in
Figure 5 .

t

If not already done, install 1/2” conduit
connector in j-box.

t

Run black, white, and green wires (#14
AWG) according to the National Electrical
Code or CSA Standards and local codes and
ordinances .

t

Connect black, white, and green wires from
power supply to black, white, and green/
yellow wires in j-box respectively.

t

Close j-box cover.

Figure 5

From

control

panel

Advertising