Table 1. ventilator performance calculation – Thermador HMWB36 User Manual

Page 7

Advertising
background image

e

c

e

i

P

t

c

u

D

10" round
to 8" roun d

5 ft.

Round ,

1 ft.

straight

(per foot
length)

3-1/4" x 10"

1 ft.

3-1/4" x 12 "

(p er f oot

straight

length)

8" Di a. 17 ft.

90

° elbow

10" Dia. 24 ft .

8" Di a. 10 ft.

45

° elbow

10" Dia. 14 ft .

3 -1⁄4" x 12"

15 ft.

3-1/4" x 10"

14 ft.

90

° elbow

3-1/4" x 10 "

8 ft.

3-1/4" x 12 "

9 ft.

45

° elbow

3-1/4" x 10"

33 ft.

3-1/4" x 12"

36 ft.

90

° flat elbow

10" round transition
to 3-1/4" x 10" or
3-1/ 4" x 12"

9 ft.

3-1/4" x 10" or
3-1/4" x 12" to
10" round transiti on

6 ft.

10" round to 3-1/4" x 10"

16 ft.

3-1/4" x 12" transiti on

13 ft.

90

° elbow

3-1/4" x 10 "

9 ft.

3-1/4" x 12" t o 10" round

8 ft.

transiti on 90

° elbow

Roun d

8" Dia. 32 ft.

wall c ap

10" Dia. 41 ft.

with damper

3-1/4" x 10"

24 ft.

3-1/4" x 12" wall cap

26 ft.

with damper

Round

8" Dia. 44 ft.

roof c ap

10" Di a. 56 ft .

Us e this chart to compute maximum
permissable lengths for duct runs to
outdoors .

Note: Do not exceed maximum permissable
equivalent lengths!

Maximum recommended duct
length for these hoods: 150 feet

Fl exible ducting:
If flexible metal duct ing is used, all
the equivalent feet values in the table
should be doubled. The flexible
metal duct should be straight and
smooth and extended as much as
possible.

Do NOT use flexible plastic ducting.

Total Duct Run

Note:

Any home ventilation system, such as a

gas furnaces, gas water heaters and other naturally
vented systems. To minimize the chance of interruption
of such naturally vented systems, follow the heating
equipment manufacturer’s guidelines and safety
standards such as those published by NFPA and ASHRAE.

*Hoods are supplied with a 10"

round transition. A locally
supplied transition is required
for other sizes.

Note: Outlet on top of hood is
8-1/8" x 8".

Table 1. Ventilator performance calculation

7