Symptom

Probable

Cause

Corrective Action

Recommended Tools

NO DISPLAY

600EA

Power Issues














Control Panel







Power Supply


Cables

• Set meter to AC voltage and test wall

outlet to 120 VAC.

• Turn power switch on

• Does power switch lamp come on?

• Yes – go to control panel.

• No- remove rear cover.

• Check voltage input to switch, is it 120

VAC? If yes – replace switch. If no –
continue on.

• Check voltage at end of power cord.

• No voltage? Replace cord.

• Check fuse in power inlet.

• Replace fuse or replace power inlet and

wires.

--------

• Check connection to the display.

• Reseat connection.

• Set meter to DC volts, unplug display

and check voltage between pin 1and pin
2.

• If 12VDC is present – replace control

panel.

--------

• Check voltage between pin 2and pin 3at

the power supply.

• If 12 VDC present – replace power

supply.

--------


• Perform a continuity check on the cables

leading to the control panel.

• Replaced damaged cables.














Multi-meter