Symptom

Probable

Cause

Corrective Action

Recommended Tools

NO CONTACT

HEART RATE

750E, 750EA

Dirty Sensors



Console Set/

Wiring








Wire Connections

Note:

You must pedal at least
30 RPM when
performing any voltage
test. You may require the
assistance of another
person when performing
voltage checks.



Multi-meter

Double sided tape

Support Services 800-883-8783

Mon-Fri 8:30am-5:00pm Central Time Zone

Fax: 636-272-7148

Page 7

• Verify hand pulse sensors are clean.

--------


• Set meter for continuity.

• Remove Console set.

• Check for continuity in both sets of

hand pulse sensors between the console
set and hand pulse sensor plates.

• If continuity is OK – Replace Console

set. If no- continue on.

--------



• Check wire connections @ handlebar

console mast joint

• Check connections of wires to hand

pulse sensor by removing hand pulse
sensor plates.

• To remove hand pulse sensor plates

carefully pry under one end to free them
from the plastic handgrips.

• Bad connections? - Reconnect/ Replace

bad wires.

• Recheck continuity.