Ta-890, User manual – Turbosound LMS-D6 User Manual

Page 83

Advertising
background image

user manual

TA-890

TA-890 user manual

Page 83

Pin 1

Screen - connect to chassis of the unbalanced

equipment, or left disconnected at the unbalanced end

Pin 2

signal hot

Pin 3

Signal cold

Polarity

In accordance with international standards, T series amplifiers are supplied with Pin 2 hot (+),
so a positive (+V) input gives a positive (+V) output from the positive (+) output terminals.

Input Impedance

Each amplifier channel has an input impedance of 10k

Ω, seen between pins 2 & 3 of the XLR.

When used with the LMS-D6 Loudspeaker Management System, distribution amplifiers are
not required when a large number of T-25 or T-45 amplifier inputs are driven in parallel.

Gain and Sensitivity Settings

Gain settings are changed internally by simple jumper links. Two rows of pins marked - GAIN
A and GAIN B - are situated on the input PCB (PCB701). A jumper link sets the gain and the
settings are as follows:

Link 1 & 2

Gives 32dB gain

Link 3 & 4

Gives 26dB gain

Link 2 & 3

Gives approx 37.5dB gain

NOTE: Factory setting is normally link 1 & 2 = 32dB gain.

Setting higher gain does not change the maximum available power but changes the level of
signal input to achieve maximum power. In any case, provided that the input signal is less
than 20dBu/7.7V, the built in limiter circuit will prevent distortion within the amplifier.