Diagnostics – True Fitness True 400 User Manual

Page 40

Advertising
background image

Diagnostics

37

E1:STALL

Incline not moving when commanded
to.

E2:OVERSPEED

This error occurs when an acceleration
>2.1 mph occurs. Error cleared by
turning off power switch then turning
it back on.

E2:CAL

Feedback cannot reduce or increase
speed to target. Error cleared by
calibrating.

E3:RECAL

This error occurs when a data error is
detected on the EEprom, replace the
control panel.

E5:SENSOR

This message is displayed when there
is no speed feedback.

Diagnostics - Service Messages

The following service messages will be displayed as they
occur, as well as for the subsequent six safety key insertions.
These messages will be displayed until a key is pressed.
Every time these messages are displayed, an audible will
sound twice.

S1:LUBE

This message is displayed when lubrication of
the deck is recommended.

S2:CLEAN

This message is displayed every 500 miles.
Prompt to clean treadmill.

S3:MOTOR

This message is displayed every 2500 hours.
Prompt to check motor brushes.

Advertising