1 recording while formatting, 6 individual clock mode, 7 error messages – Tascam DA-78HR User Manual

Page 51: 6 individual clock mode 8.7 error messages, 6, “individual clock mode, 8 - synchronization with other dtrs units

Advertising
background image

8 - Synchronization with other DTRS units

TASCAM DA-78HR

51

3

Press the

CHASE

key on all of the slave DTRS

units. The indicator will flash.

4

Press

FORMAT/Fs

twice within five seconds, on

each of the DTRS units (master and all slaves)
so all machines are ready to start formatting.

If you press the

CLEAR

key while the

FORMAT

indicator is lit steadily, you will cancel the for-
mat operation.

5

Select the same sampling rate (48 kHz or
44.1 kHz) on each DTRS unit.

Any slave DTRS unit which has a different
sampling frequency selected from that selected
on the master will display an error message.

6

Press and hold

PLAY

and press

RECORD

on

the master. All slave units’

CHASE

indicators

will light steadily, and the tapes will start to be
formatted in synchronization.

8.5.1 Recording while formatting

As with a single-machine format (5.1.4, “Recording
while formatting”
), it is possible to record while for-
matting on multiple machines.

You may want to use this feature when making a live
multi-machine recording, and there has not been time
to format all the tapes in advance of the performance.

Remember that you should let the tapes run to the
end—you should not halt the formatting/recording
process part of the way through the tape.

8.6 Individual clock mode

There are some circumstances where it may be nec-
essary to use independent reference clocks on a chain
of DTRS units when TC time mode (see 9.2, “Tape
timecode mode”)
is selected.

There are two settings,

AUTO

and

INDVID

(individ-

ual).

AUTO

is the default, and the unit behaves as fol-

lows when this is selected.

In individual mode, the unit behaves as follows:

1

Press the

SHIFT

key so that the

SHIFT

indicator

is flashing, and press the

MENU

key, until the

counter shows

SYSTEM--

(

SYSTEM--).

2

Press the

SUB MENU

key until the display

briefly shows

CLOk. MODE

(

CLOK MODE

) and

then changes to the current setting.

3

Use the and keys to change between the

AUTO

(

AUTO

) and

INDViD

(INDVID)

modes.

8.7 Error messages

These error messages refer to DTRS
synchronization:

E. DIO

(

E DIO

)—appears if the digital cable is not

connected. Re-connect the correct cable to the

DIGITAL I/O

connector.

E. CLOC

(

E CLOC

)—appears when the sync cable is

not connected, the master has been turned off, or the
master’s sampling frequency is different from that of
the slave unit’s. Recheck these parameters.

If either of these messages appears, correct the fault
to return to normal operation.

Slave unit’s
Time Mode

Master DA-78HR

Slave DA-78HR units

ABS

All clock sources

DTRS sync

TC

Internal

Internal

Word sync

DTRS sync

Slave unit’s
Time Mode

Master DA-78HR

Slave DA-78HR units

ABS

All clock sources

DTRS sync

TC

Internal,

WORD

or

DIGITAL IN

Advertising