Toshiba, Group:panel control parameters – Toshiba Adjustable Speed Drive H3 User Manual

Page 38

Advertising
background image

TOSHIBA

DIRECTION SELECTION

25

Forward/reverse

0: Reverse

-

1

9-5

(FORWARD/REV)

1: Forward

STOP PATTERN

26

Stop pattern selection

0: Decelerated stop

-

0

9-5

SELECTION

1: Coast stop

FUNDAMENTAL PARAM

27

Fundamental parameter #1 or #2

1: Fundamental

-

1

9-5

SWITCHING

selection

parameter #1

2: Fundamental

parameter #2

ACCEL/DECEL #1/#2

28

Acc/dec #1 or #2

1: Acc/dec #1

-

1

9-6

SELECTION

selection

2: Acc/dec #2

PANEL RESET

29

Panel reset selection

0: All possible

-

0

9-6

SELECTION

1: Only OL can be

reset

2: Only OL, OC1,

OC2, OC3 can be
reset

PANEL FEEDBACK

30

Panel feedback control

0: On (valid when

-

0

9-6

CONTROL

(PID, speed feedback, drooping)

panel operation is
selected)

1: Off (invalid when

panel operation is
selected)

8 - 3

GROUP:PANEL CONTROL PARAMETERS

PARAMETER

DESCRIPTION

LIQUID CRYSTAL DISPLAY

ADJUSTMENT

RANGE

ITEM

NO.

PAGE

NO.

DISPLAY

RESOLUTION

FACTORY

SETTING

Advertising