( 2 ) 1P SR (1 Pulse Trigger Sync Reset)

Charge begins to accumulate after the trigger input to the RGB terminal, the vertical sync signal is reset and
frame images are output.

(2. 1) 1 Pulse Trigger SYNC-RESET Picture Output Timing

*1: Externally input signal

*2: Exposure time is determined by the setting of "7. 2 (1.3) Changing each setting in E.TRG mode".

*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro-

nized to this and output.

Note:

When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.

About 1

µ

s

Exposure completion

0 to 1H*

3

Exposure period*

2

Video output

VIDEO INDEX

VD OUT

Trigger*

1

796H (Partial scanning OFF)
387H (Partial scanning 60fps)
258H (Partial scanning 90fps)

Negative polarity mode

Positive polarity mode