(3. 2) Pulse Width Trigger SYNC-NON RESET Picture Output Timing (at Time of Internal Sync)

*1: Externally input signal

*2: Exposure time = Trigger pulse width + 6

µ

s

(Valid trigger pulse width is 2

µ

s or greater for external trigger shutter operation.)

*3: As long as there is no external sync input, the internal VD will be output when SJ01 is set to HD/VD output

position.

*4: Video is output at the falling edge of the internal VD following completion of the exposure period.

The video and the VIDEO INDEX have a paired relationship.

Note:

When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.

About 1

µ

s

Exposure period*

2

Video output

796H (Partial scanning OFF)
387H (Partial scanning 60fps)
258H (Partial scanning 90fps)

VIDEO INDEX

VD OUT*

3

Trigger*

1

Exposure period*

2

Negative polarity mode

Positive polarity mode

About 7

µ

s