Trimble Outdoors AgGPS 252 User Manual

Page 66

Advertising
background image

B Third-Party Interface Requirements

6 0 AgGPS 252 Receiver User Guide

VCD (Vision
Display
Controller)

Rockwell

NMEA

GGA, GLL,
VTG, ZDA

4800

8-N-1

1 Hz

50166, or
30945 plus
50581

Swath XL

Midtech

NMEA

GGA

19200

8-N-1

5 Hz

50166, or
30945 plus
50581

Caterpillar
Cebis Yield
Monitor

Claus

NMEA

GGA

4800 or
9600

8-N-1

1 Hz

50166, or
30945 plus
50581

AGCO
FieIdStar
Yield
Monitor

4

AGCO

NMEA

GGA, VTG,
GSV, GSA

4800

8-N-1

1 Hz

39903 plus
50581

1

P/N 39903 replaced old Ag Leader cable P/N 30660.

2

Connect to Aux port.

3

Older GreenStars with version 5.3P mapping processor software require 9600 baud. Older GreenStars

with version 5.3R mapping processor software require 4800 baud.

4

AGCO unit requires a null modem RS-232 connection. Ag Leader cable P/N 39903 is wired correctly for

connection.

Table B.2

Third-party hardware interface requirements (continued)

Hardware

Company

Protocol

NMEA
messages

Baud

Other

Pos
rate

Cable P/N

Ag252_100B_UserGuide_ENG.book Page 60 Thursday, July 28, 2005 4:06 PM