TOA Electronics C-RM500 User Manual

Page 25

Advertising
background image

25

1. 16 INPUT*

1

Select this setting when the 16 channels Multi-Switcher is connected to the
switcher control terminal (RS-485).
Select this setting when the system includes a switcher other than Multi-Switcher
or Smart Switcher, and the number of control channels is 16 or less.

2. 9 INPUT A*

1

Select this setting when the 9 channels Multi-Switcher is connected to the
switcher control terminal (RS-485) and Camera 9's 4-segment split-screen display
is set for "OFF" in the Multi-Switcher settings.

3. 9 INPUT B*

1

Select this setting when the 9 channels Multi-Switcher is connected to the
switcher control terminal (RS-485) and Camera 9's 4-segment split-screen display
is set for "ON" in the Multi-Switcher settings.

4. 16 INPUT-2*

1

Select this setting when the 16 channels Multi-Switcher is connected to the
switcher control terminal (RS-232C).

5. 9 INPUT A-2*

1

Select this setting when the 9 channels Multi-Switcher is connected to the
switcher control terminal (RS-232C) and Camera 9's 4-segment split-screen
display is set for "OFF" in the Multi-Switcher settings.

6. 9 INPUT B-2*

1

Select this setting when the 9 channels Multi-Switcher is connected to the
switcher control terminal (RS-232C) and Camera 9's 4-segment split-screen
display is set for "ON" in the Multi-Switcher settings.

7. SMART

Select this setting when a Smart Switcher is connected to the switcher control
terminal (RS-232C). Confirming this setting will cause the unit to wait for the entry
of the number of connected Smart Switchers.

Enter the number of Smart Switchers connected to the system. If the number has
already been set, the set number is displayed.
Confirm the number of switchers with the SET key.

Note: Up to 8 Smart Switchers can be connected. Be sure to enter the correct

number. If the wrong number is entered, such symptoms will occur that
unconnected cameras are selected or connected cameras cannot be
selected.

8. OTHER 16*

2

Select this setting when the system includes a switcher other than Multi-Switcher
or Smart Switcher, and the number of control channels is 16 or less.

9. OTHER 16

64*

2

Select this setting when the system includes a switcher other than Multi-Switcher
or Smart Switcher, and the number of control channels is between 17 and 64.

10. OTHER*

2

Test mode

S W I T C H E R

7 . S M A R T

1

6.4.2. Switchers

Sets the type of switcher to be connected to the unit.

Step 1. Press the Menu key to display the menu screen.

Step 2. Tilt the joystick up or down to select "SWITCHER" and confirm it with the SET key.

The setting contents will appear on Line 2.

Step 3. Tilt the joystick left or right to select one the following setting contents and confirm it with the SET key.

S W I T C H E R

1 . 1 6 I N P U T

[Setting contents]

*

1

Power synchronization cannot be chosen by setup menu of the camera in this setting.

*

2

Camera alarm is unreceivable in this setting.

Note: The switcher type is set to "4. 16 INPUT-2" by the factory.

Advertising