Programming Codes

iTherm

®

280 Programmer’s Guide

Page 228

Rev C

28-07764

Function

Enter Test Mode

ASCII

[GS] ( A <2> <0> <n> <m>

Hexadecimal 1DH 28H 41H <2> <0> <n> <m>
Decimal

<29> <40> <65> <2> <0> <n> <m>

Description This command places the printer into test mode based on the parameters <n>

and <m>.

Where <n>

may be 0, 1, 2, 48, 49, or 50. It is intended to select the print station. The
iTherm

®

280 will accept any of these values

Where <m> 1 or 49 Selects Hex Dump mode. You must press the * Button to exit this mode

2 or 50 Selects Printer Configuration print out.
3 or 51 Selects Rolling ASCII test pattern. You must press * Button to exit this
mode.

Function

Print counter

ASCII

[GS] c:

Hexadecimal 1DH 63H
Decimal

<29> <99>

Description Sets the serial counter value in the print buffer and increments or decrements the

counter value.

• After setting the current counter value in the print buffer as print data (a
character string), the printer counts up or down based on the count mode set

Function

Initialize maintenance counter

ASCII

[GS] g 0 m nl nh:

Hexadecimal 1DH 67H 30H
Decimal

<29> <103> <48>

Description

Initializes the resettable maintenance counter to 0.

• nl, nh specifies the maintenance counter number as (nl + nh x 256)

Counter number

Counter [Unit]

Hex

Decimal

14

20

Number of line feeds: Roll paper

15

21

Number of energizing head: Roll paper

32

50

Number of autocutter operation

46

70

Print operation time

• Frequent write command executions by this command may damage the NV
memory. Therefore, it is recommended to write to the NV memory no more than
10 times a day.

• While processing this command, the printer is BUSY while writing data to the
NV counter memory and stops receiving data. Therefore it is prohibited to
transmit data including the real-time commands during the execution of this
command