Toshiba H1 Series User Manual

Page 234

Advertising
background image

TMP92CZ26A

92CZ26A-231

(6) Refresh control

The TMP92CZ26A supports two kinds of refresh commands: Auto Refresh and Self Refresh.

(a) Auto Refresh

When SDRCR<SRC> is set to “1”, the Auto Refresh command is automatically issued at

intervals specified by SDRCR<SRS2:0>. The Auto Refresh interval can be specified in a
range of 47 states to 1248 states (0.78

μs to 20.8 μs at f

SYS

= 60 MHz).

The CPU operation (instruction fetch and execution) is halted while the Auto Refresh

command is being executed. Figure3.10.6 shows the Auto Refresh cycle timing, and

Table3.10.3 shows the Auto Refresh interval settings. The Auto Refresh function cannot be
used in IDLE1 and STOP modes. In these modes, use the Self Refresh function to be

explained next.

Note: A system reset disables the Auto Refresh function.

Figure3.10.6

Auto Refresh Cycle Timing

Table3.10.3 Auto Refresh Intervals

Unit [

μs]





SDRCR<SRS2:0>

Frequency (System Clock)

SRS2 SRS1 SRS0

Auto

Refresh

Interval
(states)

6 MHz

10 MHz

20 MHz

40 MHz

60 MHz

80 MHz

0 0 0 47

7.8

4.7

2.4 1.18 0.78 0.59

0 0 1 78 13.0

7.8

3.9 1.95 1.30 0.98

0 1 0 156

26.0

15.6

7.8 3.90 2.60 1.95

0 1 1 312

52.0

31.2

15.6 7.80 5.20 3.90

1 0 0 468

78.0

46.8

23.4 11.70 7.80 5.85

1 0 1 624

104.0

62.4

31.2 15.60 10.40 7.80

1 1 0 936

156.0

93.6

46.8 23.40 15.60 11.70

1 1 1 1248

208.0

124.8

62.4 31.20 20.80 15.60

SDCLK

SDCKE

SDLUDQM

SDLLDQM

Auto Refresh

2 states

SDCS

SDRAS

SDCAS

SDWE

Advertising
This manual is related to the following products: