Thermador PRO GRAND PRD48 User Manual

Page 7

Advertising
background image

English 5

F

IGURE

1: C

ABINET

C

LEARANCES


For 48” Ranges {48” (1219mm) 54” (1372mm), or 60” (1524mm) Wide Hood
{54” (1372mm) for Island

For 36” Ranges {36” (914mm) or 42” (1067mm) Wide Hood
{42” (1067mm) or 48” (1219mm) for Island



48” Range - 48” (1219mm)

36” Range - 36” (914mm)

of combustible material

Min. distance between overhead cabinets

30” (762mm) min. from bottom
of Overhead Hood to cooking
surface. 36” (914mm) min. If
hood contains combustible

materials.

minimum

18” (457mm)

36” (914mm) or 48” (1219mm)

13” (330mm)

Max Cabinet

Depth

Range width

5” (127mm)
min. to
combustible

material
(both sides).

CAUTION!

See Figure 2

36” (914mm) Min.

material
from cooking
Surface

to combustible

For Electrical & Gas Supply zones,
see Figure 3. Zone sizes & positions differ
according to model.

as defined in the “National Fuel Gas Code” ANSI Z223.1,

Current Edition). *The range height is adjustable. The level
of the range top must be at the same level or above the
countertop level.

*35

7

/

8

” (911mm) Min. range height

*36

3

/

4

” (933mm) Max range height

with leveling legs fully extended.

with leveling legs fully retracted.

Gas
Zone

Electrical
Zone

sidewall