Performance data – Trane XV 90 User Manual

Page 9

Advertising
background image

9

Pub. No. 22-1682-05-0802 (EN)

Performance
Data

TUY100R9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOOR

UNIT SIZE

(TONS)

AIRFLOW

SETTING

(See Notes)

DIP SWITCH SETTING

EXTERNAL STATIC PRESSURE

SW 1

SW 2

SW 3

SW 4

0.1

0.3

0.5

0.7

0.9

3.0

LOW

(350 CFM/TON)

ON

ON

OFF

ON

CFM

WATTS

1040

165

1040

220

1040

270

1030

320

1030

375

NORMAL

(400 CFM/TON)

ON

ON

OFF

OFF

CFM

WATTS

1210

235

1210

285

1230

360

1230

415

1230

475

HIGH

(450 CFM/TON)

ON

ON

ON

OFF

CFM

WATTS

1340

390

1370

390

1400

465

1390

525

1370

580

3.5

LOW

(350 CFM/TON)

OFF

ON

OFF

ON

CFM

WATTS

1200

225

1220

280

1230

365

1250

425

1230

485

NORMAL

(400 CFM/TON)

OFF

ON

OFF

OFF

CFM

WATTS

1390

335

1430

425

1430

495

1430

560

1400

590

HIGH

(450 CFM/TON)

OFF

ON

ON

OFF

CFM

WATTS

1590

490

1590

575

1590

625

1580

685

1420

615

4.0

LOW

(350 CFM/TON)

ON

OFF

OFF

ON

CFM

WATTS

1370

325

1420

415

1430

490

1340

550

1410

595

NORMAL

(400 CFM/TON)

ON

OFF

OFF

OFF

CFM

WATTS

1640

515

1640

585

1640

655

1590

680

1420

615

HIGH

(450 CFM/TON)

ON

OFF

ON

OFF

CFM

WATTS

1840

700

1840

780

1770

795

1630

725

1470

655

NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position.
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.

TUY100R9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

1st Stage Capacity =
2nd Stage Capacity =

62,000
93,000

AIRFLOW

SETTING

DIP SWITCH SETTING

EXTERNAL STATIC PRESSURE

SW 7

SW 8

0.1

0.3

0.5

0.7

0.9

HEATING

1ST

STAGE

LOW

ON

ON

CFM

TEMP. RISE

WATTS

920

60

130

920

60

180

920

60

220

920

60

280

920

60

320

MEDIUM LOW

OFF

ON

CFM

TEMP. RISE

WATTS

1020

54

165

1020

54

220

1020

54

260

1010

55

310

1000

56

365

NORMAL **

ON

OFF

CFM

TEMP. RISE

WATTS

1160

48

220

1160

48

260

1160

48

325

1160

48

390

1150

48

430

HIGH

OFF

OFF

CFM

TEMP. RISE

WATTS

1350

41

320

1380

40

400

1400

40

470

1400

40

540

1390

40

585

HEATING

2ND

STAGE

LOW

ON

ON

CFM

TEMP. RISE

WATTS

1290

67

275

1290

67

355

1330

65

430

1340

64

490

1320

65

545

MEDIUM LOW

OFF

ON

CFM

TEMP. RISE

WATTS

1410

61

3561

1460

59

455

1460

59

520

1460

59

590

1370

63

590

NORMAL **

ON

OFF

CFM

TEMP. RISE

WATTS

1640

53

530

1640

53

590

1640

53

660

1600

54

695

1410

61

620

HIGH

OFF

OFF

CFM

TEMP. RISE

WATTS

1970

44

855

1920

45

895

1780

48

820

1660

52

760

1520

57

695

NOTES:
** Factory setting

Advertising
This manual is related to the following products: