SECTION 6: TEST AND ADJUSTMENT

BURNER AIR ADJUSTMENT

All burners are adjusted for proper flame
characteristics at time of assembly.

All burners should exhibit flames which are blue and
stable, with no yellow-tipping, lifting or excessive
noise when operating on either natural or LP gases.

If any of the flame characteristics noted above are
observed, check the burner for dirt or residue in
the ports, spider webs, etc., and clean or repair as
necessary.

LIGHTING INSTRUCTION

For Electronic Ignition:

1. Make sure that all knobs are turned to the OFF

position.

2. Turn the knob to LITE position and immediately

press the ignition switch. The burner will light
within 4-10 seconds.

3. Adjust control knob to the desired flame setting.

For Manual Ignition:

1. Check that the burner caps are in correct

position, shown on Page 13.

2. Turn control knob to the “LITE” position.

3. Place the lighted match on the burner cap ports.

4. Adjust control knob to the desired flame setting.

WARNING: Remove the stainless steel burner cover before attempting to
light the appliance. Failure to remove the cover could allow gas to accumulate
which could cause an explosion.

IF YOU SMELL GAS, DO NOT ATTEMPT TO LIGHT ANY BURNERS.

INSTALLER CHECKLIST

INSTALLATION

— Placement of unit.
— Specified clearances maintained to combustible

or noncombustible surfaces as applicable.

— The burner box area is free of any packing

materials and that the burners are properly
located and installed.

— Burner caps properly positioned and seated on

burner bases.

ELECTRICAL

— Properly grounded receptacle is present for

unit.

GAS SUPPLY

— Appliance is connected to the proper type of

gas supply.

— Manual gas shut off valve is installed in an

accessible location (with unit installed in
enclosure for built-in installations).

— Unit tested and free from gas leaks.

— Gas supply pressure does not exceed 14" W.C.

— If the unit is to be used with propane gas, verify

that the LP gas supply has its own high pressure
regulator.

12