OPERATION PROCEDURE

OPERAT

ION

PROCED

URE

27

OPERATION BASICS

STARTING AND STOPPING THE MACHINE

Power Switch

The power switch is provided on the power supply box.
Press the power switch at "O" side to turn the power OFF or at "I" to turn the
power ON.

EMERGENCY STOP Switch

Use the EMERGENCY STOP switch to stop the machine in an emergency.
When the EMERGENCY STOP switch is pressed, the main shaft stops rotating
and the EMERGENCY STOP switch is locked in the pressed state.
Turn the switch in the arrow direction to release the lock.

START and STOP Keys

The START key, when pressed, starts machine operation and the STOP key,
when pressed, stops the machine.
The needle bar stops at the upper dead point when the STOP key is pressed.

FD07

When reapplying the power, turn
the switch OFF and then turn it
back ON after several seconds.

OFF

ON

Power switch