Inverter operating command mode status (fe45), Inverter operating frequency mode status (fe46) – Toshiba TOSVERT VF-S11 User Manual
Page 51
Advertising

E6581222
49
Inverter operating command mode status (FE45)
The monitor of the command mode that the present condition is enabled
Data
Enabled command
0
Terminal board
1
Operation panel
2
Serial communication
Inverter operating frequency mode status (FE46)
The monitor of the frequency command mode that the present condition is enabled
Note that Preset speed operation frequencies is given the priority independent of the frequency
mode, in which case this monitor will be disabled, in case Preset speed operation frequencies is se-
lected.
Data
Enabled frequency
0
Potentiometer at Operation panel
1
VIA
2
VIB
3
Operation panel
4
Serial communications
5
TB up down frequency
6
VIA + VIB