Step 2: Cabinet Preparation

4"

14"

4"

A

B

C

Figure 1.

Dimensions

Trim Kits

Width (B)

28

-1

/

2

"

±

1

/

16

MT30B; MT30W; MT30S

25

-1

/

2

"

±

1

/

16

MT27B; MT27W; MT27S

Height (A)

17"

±

1

/

16

All Trim Kits

Depth (C)

24"

±

1

/

8

All Trim Kits

Outlet should be in
the shaded area.

Microwave
Cutout

Top of
microwave
shelf

1

-3

/

4

"

(45 mm)

}

Thermador
single wall
oven cutout

Figure 2.

The cabinet cut out dimensions are shown in
Figure 1.

It is good practice, when microwave oven is
installed at the end of a cabinet run, adjacent
to a perpendicular wall or cabinet door, to al-
low at least 1/4" space between the side of
the trim and the wall/door

Your microwave oven can be installed into a
cabinet or wall by itself or above any of the
following : Thermador wall ovens C271, C301,
CM301, S301, SC301, CJ301 or Thermador
Warming Drawers WD 27 and WD 30 (See
Figure 2).

Outlet should be in the shaded area as indi-
cated in Figure 1.

Step 3: Electrical
Installation

The Thermador micro-

wave oven is equipped with
a grounded cord. The wall
receptacle must be in-
stalled and grounded in ac-
cordance with the national
electrical code. Also, elec-
trical connections and
grounding must comply
with all applicable local
codes.

The electrical require-

ments for a separate circuit
serving only this micro-
wave oven are: 120v, 60Hz,
15amp.

Warming

Drawer

cutout

Microwave

cutout

1

-1

/

2

"

(38 mm)

}

Advertising