Terminal Functions (Continued)

100-/1000-Mbit/s MAC interface [media-independent interface (MII) mode]

TERMINAL

NAME

I/O

INTERNAL
RESISTOR

DESCRIPTION

M08_COL

I

Pulldown

Collision sense. Assertion of M08_COL during half-duplex operation indicates network collision.
Additionally, during full-duplex operation, transmission of new frames does not commence if this
terminal is asserted.

M08_CRS

I

Pulldown

Carrier sense. M08_CRS indicates a frame carrier signal is being received.

M08_EWRAP

O

None

Enable wrap. M08_EWRAP reflects the state of the loopback bit in the PCS8Control register.

M08_GTCLK

O

None

Unused. This terminal can be left unconnected.

M08_LINK

I

Pulldown

Connection status. M08_LINK indicates the presence of port connection.

– If M08_LINK = 0, there is no link.
– If M08_LINK = 1, the link is OK.

M08_LREF

O

None

Renegotiate. M08_LREF indicates to the attached PHY device that this device wishes to negotiate
a new configuration.

– Following a 0-to-1 transition of neg in PortxControl, M08_LREF is asserted low, and
remains low until M08_LINK goes low. If M08_LINK was already low, M08_LREF is still
activated for at least one cycle.
– M08_LREF is asserted low for as long as initd in SysControl = 0, regardless of the state
of M08_LINK.

M08_RCLK

I

Pullup

Receive clock. Receive clock source from the attached PHY or PMI device.

M08_RFCLK

I

Pullup

Transmit clock. Transmit clock from the attached PHY or PMI device.

M08_RXD7
M08_RXD6

I

Pullup

Unused. These terminals can be left unconnected.

M08_RXD5

I/O†

Pullup

IEEE Std 802.3x pause frame support selection

– If pulled low either internally or by the attached PHY or PMI device, M08_RXD5 causes the
port to not support pause frames.
– If not pulled low, the port does not support pause frames.

M08_RXD4

I/O†

Pullup

Duplex selection [force half duplex (active low)]

– If pulled low either internally or by the attached PHY or PMI device, the port operates in
half-duplex mode.
– If not pulled low, the port operates in full-duplex mode.

M08_RXD3
M08_RXD2
M08_RXD1
M08_RXD0

I

Pullup

Receive data. Nibble-wide receive data from the attached PHY or PMI device. When M08_RXDV
is asserted, these signals carry receive data. Data on these signals is synchronous to M08_RCLK.

M08_RXDV

I

Pulldown

Receive data valid. M08_RXDV indicates data on M08_RXD3–M08_RXD0 is valid. This signal is
synchronous to M08_RCLK.

M08_RXER

I

Pulldown

Receive error. Indicates reception of a coding error on received data.

M08_TXD7
M08_TXD6
M08_TXD5
M08_TXD4

O

None

Unused. These terminals can be left unconnected, but are driven low.

M08_TXD3
M08_TXD2
M08_TXD1
M08_TXD0

O

None

Transmit data. Nibble-wide transmit data. When M08_TXEN is asserted, these signals carry
transmit data. Data on these signals is synchronous to M08_RFCLK.

† Not a true bidirectional terminal. It can only be actively pulled down.