Tnetx4090 thunderswitch ii, Switch – Texas Instruments THUNDERSWITCH II TNETX4090 User Manual

Page 60

Advertising
background image

TNETX4090
ThunderSWITCH II

9-PORT 100-/1000-MBIT/S ETHERNET

SWITCH

SPWS044E – DECEMBER 1997 – REVISED AUGUST 1999

60

POST OFFICE BOX 655303

DALLAS, TEXAS 75265

absolute maximum ratings over operating free-air temperature range (unless otherwise noted)

Supply voltage range, V

DD(2.5)

(see Note 1)

–0.5 V to 2.7 V

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Supply voltage range, V

DD(3.3)

(see Note 1)

–0.5 V to 3.6 V

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Supply voltage range, V

DD

a (see Note 1)

–0.5 V to 2.7 V

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Supply voltage range, DVREF (see Note 1)

1 V to 2.2 V

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Input voltage range, V

I

–0.5 V to V

DD(3.3)

+ 0.4 V

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Output voltage range, V

O

–0.5 V to V

DD(3.3)

+ 0.5 V

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Input voltage range (RSL), V

IR

DVREF – 0.35 to DVREF + 0.8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Output voltage range (RSL), V

OR

0.0 to V

DD(2.5)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Thermal impedance, junction-to-ambient package, Z

θ

JA

: Airflow = 0

11.11

°

C/W

. . . . . . . . . . . . . . . . . . . . . . . . .

Airflow = 100 ft/min

9.61

°

C/W

. . . . . . . . . . . . . . . . .

Thermal impedance, junction-to-case package, Z

θ

JC

0.94

°

C/W

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Operating case temperature range, T

C

0

°

C to 70

°

C

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Storage temperature range, T

stg

–65

°

C to 150

°

C

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

† Stresses beyond those listed under “absolute maximum ratings” can cause permanent damage to the device. These are stress ratings only, and

functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods can affect device reliability.

NOTE 1: All voltage values are with respect to GND.

recommended operating conditions

MIN

NOM

MAX

UNIT

VDD(2.5)

Supply voltage

2.5

2.6

2.7

V

VDD(3.3)

Supply voltage

3

3.3

3.6

V

DVREF

RSL reference voltage

1.8

2.0

2.2

V

VI

Input voltage

0

VDD(3.3)

V

VO

Output voltage

0

VDD(3.3)

V

VIH

High-level input voltage

2

VDD(3.3)

V

VIL

Low-level input voltage (see Note 2)

0

0.8

V

IOH

High-level output current

–2

mA

IOL

Low-level output current (except LED_DATA)

2

mA

IOL

LED_DATA (terminal AE19)

0

8

mA

VIHR

High-level input voltage (RSL)

DVREF+0.35

DVREF+0.8

V

VILR

Low-level input voltage (RSL) (see Note 2)

DVREF–0.35

DVREF–0.8

V

IOHR

High-level output current (RSL)

–10

10

µ

A

IOLR

Low-level output current (RSL)

0

80

mA

NOTE 2: The algebraic convention, in which the more-negative (less-positive) limit is designated as a minimum, is used for logic-voltage levels

only.