Unit operation, Emergency and test operation, Test operation – Toshiba RAS-18LAH-A User Manual

Page 23: Emergency operation

Advertising
background image

UNIT OPERATION

EMERGENCY AND TEST OPERATION

Test Operation

This operation is used for checking after unit installation.

• Press the TEST button.
• Press the TEST button once more after checking to activate remote control. If there is any input

signal ( remote control signal or EMERGENCY button pressed ) during test operation, the TEST mode will
change to the input signal mode.

• The setting conditions of the test operation are as follows:

- Operation mode : COOL
- Fan speed : HIGH
- Timer mode : Disable
- Discharge air direction : SWING

Emergency Operation

When the remote control is lost, damaged or the battery is discharged, the EMERGENCY button can be used
to run the unit.

• Press the EMERGENCY button at the off mode condition.

- The unit operates automatically according to the room temperature by selecting either the cooling or

the heating operation.

• If you want to stop the emergency operation, push the EMERGENCY button again or operate the remote control.
• The setting conditions of emergency operation are as follows:

- Operation mode : AUTO
- Preset temperature : 25

°

c

- Fan speed : AUTO
- Timer mode : Disable
- Discharge air direction : Set automatically according to operation mode. ( Refer to p. 20 )

EMERGENCY
TEST

OWNER

,

S MANUAL - 21

Advertising