Scheduled operations

11

EN

7

Set what is to be operated at the time which was
set in step 6
.

* The settings can be established in any sequence.

The functions will differ depending on the model and
system.

I. Selecting and setting operation/stop

Each time the

button (48) is pushed, what

appears on the timer function display changes in
the following sequence. Stop pushing the button
when the desired operation blinks on the display.

II. Selecting and setting the operation mode

Each time the

button (34) is pushed, what

appears on the operation mode display (1)
changes in the following sequence. Stop pushing
the button when the operation mode blinks on the
display.

III. Setting the temperature

Each time the TEMP

and

buttons (49) are

pushed, what appears on the numeric display
changes in the following sequence. Stop pushing
the buttons when the target temperature to be set
blinks on the display.

IV.Setting the restriction on the button operations
• Each time the

button (34) is pushed while the

button (43) is held down, the central control

display changes from off to blinking or vice versa.
To place the restriction on the button operations,
ensure that the display is blinking.
* The

button (32),

button (34) and

TEMP

and

buttons (49) are the buttons

whose operation will be restricted by this setting.
For further details, refer to the “Selecting the
remote controller functions” section.

V. Setting the save operation

Each time the

button (38) is pushed, the

numeric display and save operation display

change in the following sequence. Stop pushing
the button when the desired save operation mode
(mode 0 to 3) blinks on the display.

8

Push the

button (42), and enter all the items in

steps I to V above and the operation time
together.

• The display of all the setting items changes from

blinking to lighted.

9

In addition:

I. To input the settings into the different program

number for the same day of the week, repeat the
operations from step 4.

II. To move to a different day of the week and input

the program, repeat the operations from step 2.

10

Finally, push the

button (46) to return to the

original screen.

• An underbar is displayed under the selected day of

the week.

Operation

continue

(No display)

Operation

stop

Operation

start

Auto

Operation mode

Heating

Dry

(No display)

Fan

Cooling

or

Push

4 seconds

or more

Push

4 seconds or more

Frost protection
operation

Save operation

mode

Description

Mode 0

No save operation

Mode 1

Save operation with 75% upper limit

Mode 2

Save operation with 50% upper limit

Mode 3

Compressor shutdown

Mode 0

Mode 1

Mode 2

Mode 3

MB FRIGO Grupa d.o.o., Bani 81, 10010 Zagreb, www.toshiba.hr, e-mail: [email protected]