Troubleshooting

Before requesting repair work

Check out the following points before requesting repair
work.

The scheduled operation is not performed even
though the set time is reached.

• The scheduled operation has not been set.
• A special holiday has been set.

The current clock time setting is blinking.

• There has been a prolonged power outage. Re-set

the current clock time and current day of the week.

There is no response when the keys are operated.

• The restriction has been set for the key operations.

Check the program.

The clock is not displayed when the power is turned
on.

• The timer operation function or follower remote

controller has been set.

• The setting for not displaying the clock has been

established.

Trouble diagnosis

<<Checks and inspections>>
• When trouble has occurred in the air conditioner, an

inspection code and the number of the indoor unit
concerned blink on the numeric display.

• Inspection codes are displayed only during operation.
• If the display has gone off, check the trouble by

following the steps in “Checking the trouble history”
below.

<<Checking the trouble history>>
• When trouble has occurred in the air conditioner, the

trouble history can be checked by following the steps
below. (Up to four events are stored in the trouble
history.)

• The trouble history can be checked whether the air

conditioner is running or shut down.

1

Push the

button (42) and

button (43)

together for at least 4 seconds.

• The numeric displays blink, and the servicing

display

and inspect display light.

2

Push the TEMP

or

button (49).

• Each time one of these buttons is pushed, the

trouble history events are displayed in numerical
order.

• The “01” code on the numeric display indicates the

latest event, and “04” the earliest event.
* Do not push the

button (41) since all the

trouble history events of the indoor units will be
deleted.

3

After checking the events, push the

button

(43) to return to the original screen.

Concerning trouble occurring in the remote
controller

”, “

” and “

blink at the same time.

• This means that trouble has occurred on the remote

controller’s circuit board. Contact your dealer.

• Normal air conditioner operations are still possible, but

no scheduled operations can be performed.

<Caution> If the problem persists even after
checking out the above points, stop operating the air
conditioner, set the ground fault interrupter to off, and
give the model number and details of the symptoms to
your dealer. Do NOT attempt to remedy the
problem yourself due to the dangers involved
.

Inspection code

Address of indoor unit
where the trouble has
occurred

Inspection code

Address of indoor unit where
the trouble has occurred

Numerical order of
trouble history events