Battery Service (Fig. 18, 19)

IMPORTANT: Before welding on the machine, dis-
connect the negative (–) battery cable from the bat-
tery to prevent damage to the electrical system.

IMPORTANT: To prevent damage to the electrical
components, do not operate the engine with the
battery cables disconnected.

Keep the terminals and entire battery case clean. To
clean the battery, wash the entire case with a solution
of baking soda and water. Rinse with clear water. Do not
get the soda solution into the battery because damage
to the battery will result. Coat the battery posts and cable
connectors with skin-over grease, or petroleum jelly to
prevent corrosion.

Check for loose battery hold-downs. A loose battery may
crack or cause the container to wear and leak acid.

Check the electrolyte solution to make sure the level is
above the plates. If the level is low (but above the plates
inside the battery), add water so the level is to the
bottom of the cap tubes. If the level is below the plates,
add water only until the plates are covered and then
charge the battery. After charging, fill the battery to the
proper level.

Electrolyte Specific Gravity

Fully charged: 1.250 - 1.280
Discharged: less than 1.240

Do not charge a frozen battery because it can
explode and cause injury. Let the battery
warm to 60

o

F (15.5

o

C) before connecting to

a charger.

Charge the battery in a well-ventilated place
so that gases produced while charging can
dissipate. Since the gases are explosive, keep
open flame and electrical spark away from the
battery; do not smoke. Nausea may result if
the gases are inhaled. Unplug the charger
from the electrical outlet before connecting or
disconnecting the charger leads from the bat-
tery posts.

Battery Specifications

BCI Group U1 Battery
200 Amp Cranking Performance at 0

o

F (17

o

C)

32 min. Reserve Capacity at 80

o

F (27

o

C)

Figure 18

1. Positive (+) terminal
2. Negative (–) terminal

Figure 19