OPERATING INSTRUCTIONS

Wait 30 seconds before readjusting the heater when the control has been turned
down to a lower setting.

WARNING

PILOT FLAME
The pilot flame should always be present when the
heater is in operation and should just touch the top of
the thermocouple tip (FIGURE 9).

If the pilot flame does not touch the thermocouple,
then the main burner is unlikely to function reliably
(FIGURE 10).

CHECKING FLAME APPEARANCE
Flames from the pilot, front and rear burner should be visually checked when the heater is installed. In addition a
periodic visual check of the flames should be made.

Annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent
malfunction and/or sooting.

Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent skin irritation
from ceramic. If the skin becomes irritated, wash gently with soap and water. Refer to manual for correct log
placement.

WARNING

Turn off heater and allow to cool before cleaning.

FIGURE 9. Pilot Flame

FIGURE 10. Incorrect Shape of Pilot Flame

MATCH LIGHTING INSTRUCTIONS
If the pilot will not light using the piezo ignitor, you can light the pilot with a match. First, locate the pilot. The
pilot is located behind the burner tube on the right end (facing the unit), inside the firebox. To light pilot with a match,
move the gas control (knob 1, pg. 19) to the pilot position and hold down. Light match and place near pilot. Once
pilot is lit, continue to hold the knob for about ten seconds. Then follow steps 7 thru 9 on page 19.