SPECIFICATIONS

Natural Gas
Manifold Pressure Setting 4" w.c.
Gas Inlet Pressure

Maximum 10-1/2" w.c.
Minimum 5" w.c.

Gas Rate

Number

Model Number

Type

Max BTU/Hr

Min BTU/Hr

of Burners

VF30IN

Manual

30,000

16,000

1

Propane / LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
Manifold Pressure Setting 10" w.c.
Gas Inlet Pressure

Maximum 13" w.c.
Minimum 11" w.c.

Gas Rate

Number

Model Number

Type

Max BTU/Hr

Min BTU/Hr

of Burners

VF30IL

Manual

30,000

16,000

1

GLOVES ARE RECOMMENDED WHEN HANDLING CERAMIC FIBER LOGS
TO PREVENT SKIN IRRITATION FROM LOOSE FIBERS. LOGS ARE FRAGILE,
HANDLE WITH CARE.

CONTENTS

Carefully inspect the contents for shipping damage and immediately inform your dealer if any damage is found.

CAUTION

VF30IN and VF30IL Vent-free Gas Room Heaters

1. Owner's manual.
2. Log box containing four (4) fiber ceramic logs, refer to installation instructions.
3. Vent-free gas heater.

CHECK THAT ALL LISTED PARTS HAVE BEEN RECEIVED

Controls - Main control has 4 positions:

1. OFF - All gas to the gas logs is shut off at the control
2. IGN - Piezo ignitor allows ignition of the pilot without the use of matches or batteries
3. PILOT - Valve position to light / maintain a standing pilot
4. ON - Gas flow to complete system, front burner ignition

Burner Control Knob - Infinite control, rotate clockwise to minimum rate and counterclockwise for maximum
rate. Adjust the control knob between Minimum and Maximum to gain the desired room temperature. The control
will automatically cycle the heater on and off to maintain the desired heat in the room. There are no exacts with
the adjustment, you will need to experiment with the setting to find what works best for you needs.